rank-math
domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init
action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/u561405614/domains/meriiti.com/public_html/wp-includes/functions.php on line 6114updraftplus
domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init
action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/u561405614/domains/meriiti.com/public_html/wp-includes/functions.php on line 6114These questions belong to ITI Trade theory which has been asked in various government exams. After solving, Mention your marks in the comment section
For More such questions & Discussions, Join Our Telegram Channel
0 of 42 questions completed
Questions:
Press the Start Quiz Button to Start the test
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading…
You must sign in or sign up to start the quiz.
You have to finish following quiz, to start this quiz:
0 of 42 questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 points, (0)
Average score |
|
Your score |
|
What is the unit of susceptance? S1M6-1
What is the resistance of the inductive coil takes 5A current across 240V, 50Hz supply at 0.8 power factor? S1M6-2
How the resonance frequency (fr) can be increased in A.C series circuit? S1M6-3
What is the main cause for below 0.5 lagging power factor in 3 phase system? S1M6-5
What is the current in neutral conductor in 3 phase unbalanced load in star connected system? S1M6-6
Calculate the apparent power in KVA of 3 phase 415V, 50 Hz, star system, if the line current (IL) is 16A at 0.8 power factor S1M6-7
What will be the readings of two watt meters (W1& W2) in 3 phase power measurement, if the power factor is zero? S1M6-8
What is the maximum value of voltage for 240 volt RMS? S1M6-9
What is the formula for Reactive Power (Pr) in an AC circuit? S1M6-11
Calculate the impedance of the circuit $$\rm{R=5\Omega,~XL=36\Omega,~XC=24\Omega}$$ S1M6-12
What is the phase displacement in a single phase AC circuit? S1M6-13
What is the relation between the line voltage ($$\rm{V_L}$$) and phase voltage ($$\rm{V_p}$$) in star connected system? S1M6-14
Calculate the line current of the 3 phase 415V 50 HZ supply for the balanced load of 3000 watt at 0.8 power factor is connected in star S1M6-15
What is the power factor in a 3 phase power measurement of two wattmeters showing equal readings? S1M6-16
Calculate the power factor of coil having resistance of $$24~\Omega$$, draws the current of 5A, at 240V/ 50HZ AC supply S1M6-17
What is the formula to calculate the impedance (Z) of the R.L.C series circuit, if the inductive reactance $$\rm{(X_L)}$$ is less than capacitive reactance $$\rm{(X_C)}$$? S1M6-18
Calculate the power factor of R.L.C circuit having resistance (R) = $$15\Omega$$, resultant reactance (X) = $$20\Omega$$ connected across 240V /50Hz AC supply? S1M6-19
Calculate the value admittance (Y) of the RLC parallel circuit connected across 240volts/50Hz AC supply and 8 Amp. Current is passed through it ? S1M6-20
What is the formula to calculate the line current $$\rm{(I_L)}$$ of this single phase R – C parallel circuit? S1M6-21
How the low power factor (P.F) can be improved in AC circuits? S1M6-22
What is the relation between the line current $$\rm{(I_L)}$$ and phase current $$\rm{(I_P)}$$ in delta connected system? S1M6-24
What is the purpose of phase sequence meter? S1M6-25
Calculate the apparent power of a star connected 3 phase load, if it is connected across 3 phase 415volt/50Hz supply at 0.8 p.f and the phase current is 10 Amps. S1M6-26
What is the P.F if one of the wattmeters reading is zero and the other reads total power in 2 wattmeter method of 3 phase power measurement? S1M6-27
What is the formula for form factor(Kf)? S1M6-28
Which electrical term is defined as the total opposition to current in AC parallel circuit? S1M6-29
Which AC circuit contains the phase relation between voltage (V) and current (I)? S1M6-30
In a 3 phase system, if the active power is 4 kw and the apparent power is 5 KVA, calculate the reactive power? S1M6-31
In which condition resonance will occur in R-LC series circuit? S1M6-32
How will you obtain positive reading in the wattmeter reads negative reading during 3- phase two wattmeter method? S1M6-33
What is the form factor (Kf) for sinusoidal AC? S1M6-34
What is the reciprocal of inductance in AC parallel circuit? S1M6-35
What relationship is illustrated in between the current and voltage? S1M6-36
Calculate the total power by two wattmeter (W1 & W2) method, if one of the wattmeter (W2) reading is taken after reversing. S1M6-37
In which 3 phase system, the artificial neutral is required to measure the phase voltage? S1M6-38
What is the line voltage in 3 phase system if the phase voltage is 240V? S1M6-39
Which formula is used to calculate Form factor $$\rm{(K_f)}$$? S1M6-40
Which formula is used to calculate the impedance (z) of a RLC series circuit? S1M6-41
What is the power factor if one of the wattmeter gives negative reading in two wattmeter method of 3 phase power measurement? S1M6-42
What is the phase displacement between phases in a 3-phase circuit? S1M6-43
Which condition is called as resonance RLC circuit? S1M6-44
Which quantity is rotating at a constant angular velocity? S1M6-45